In order to mix EX switches and QFX switches in the same VCF, you need to enable mixed-mode.   This requires all members of the VCF to reboot unfortunately:

{master:1}
imtech@sw0-24c> request virtual-chassis mode fabric mixed
fpc0:
--------------------------------------------------------------------------
Mode set to 'Fabric with mixed devices'. (Reboot required)

fpc2:
--------------------------------------------------------------------------
Mode set to 'Fabric with mixed devices'. (Reboot required)

fpc3:
--------------------------------------------------------------------------
Mode set to 'Fabric with mixed devices'. (Reboot required)

fpc1:
--------------------------------------------------------------------------
WARNING, Virtual Chassis Fabric mode enabled without a valid software license.
 Please contact Juniper Networks to obtain a valid Virtual Chassis Fabric License.

Mode set to 'Fabric with mixed devices'. (Reboot required)

{master:1}
imtech@sw0-24c>

Once you’ve cabled up your QSFP ports between the EX4300 you are adding and the QFX spines, you need to do the following:

Enable the VCF port on the QFX spine:

request virtual-chassis vc-port set pic-slot 0 port 48

 

 

 